Information
- Manufacturer: CineMassive (1.855.539.9802)
- Product: Video Walls
- Type: Video Walls
Supported Features
- Get Config
- Sync
- Controls
Components and Communication
From | To | Port | Use |
Sureview | Cinemassive | 80 | HTTP REST API Commands |
Sureview | Cinemassive | 443 | HTTPS REST API Commands |
External Configuration
Before you begin
Before you configure your CineMassive system to work with Sureview make sure you have the following:
- A licensed Cinemassive server
- An Sureview server running Device Server Service v1.1.0.6 or newer
- An Sureview server running Sureview Web v1.28.3.47 or newer.
Configuring Behaviors
To add a new Behavior in CineMassive you will first need to open the Admin menu in the top right and select Setup.
You will then need to go to the Behaviors section and click the Add button.
From here you can configure your Behavior to what is needed. Start by entering the Name and Description of the Behavior. You will then need to add the Actions you would like the Behavior to perform.
Once you have configured your Behavior you can the select Save and Continue. The new Behavior will then be available to use in Cinemassive and brought into Sureview.
Sureview Configuration
Device Setup
Field | Value |
Host | CineMassiveAddress.com |
Port | REST API Port |
Username | Username for the CineMassive system |
Password | Password for the CineMassive system |
Extra Value | Behavior Name Prefix |
Extra Value
Extra value text is used to provide a prefix to match when getting the configuration from CineMassive. All Behaviors the do not have this prefix will be ignored.
If no prefix is entered into the extra value then all Behaviors will be brought into Sureview as relays.
There are two ways which these relays can then be used in Sureview. The first of which would be to add a relay alarm action which will automatically triggered when the corresponding alarm is triggered. This will need to be setup within the V1 interface. The second is to setup an action plan event so the operator can trigger the relay in an event in V2.
Comments
0 comments